WEKO3
アイテム
携帯用24時間心拍数記録装置 : その試作と応用
https://chukyo-u.repo.nii.ac.jp/records/10364
https://chukyo-u.repo.nii.ac.jp/records/103644a7a60b9-af97-4538-8a5c-9595257b00f8
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| Item type | [ELS]紀要論文 / Departmental Bulletin Paper_02(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2016-11-14 | |||||
| タイトル | ||||||
| タイトル | 携帯用24時間心拍数記録装置 : その試作と応用 | |||||
| タイトル | ||||||
| タイトル | A PORTABLE BIO-INFORMATION MEMORY SYSTEM FOR RECORDING HEART RATES OF A WHOLE DAY | |||||
| 言語 | en | |||||
| 言語 | ||||||
| 言語 | jpn | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | departmental bulletin paper | |||||
| 雑誌書誌ID | ||||||
| 収録物識別子タイプ | NCID | |||||
| 収録物識別子 | AN00144493 | |||||
| 著者 |
山本, 高司
× 山本, 高司× 真鍋, 篤広× 加藤, 好信× 藤松, 博× YAMAMOTO, Takashi× MANABE, Atsuhiro× KATO, Yoshinobu× FUJIMATSU, Hiroshi |
|||||
| 著者所属(日) | ||||||
| 中京大学体育学部運動生理学研究室 | ||||||
| 著者所属(日) | ||||||
| 中京大学体育学部運動生理学研究室 | ||||||
| 著者所属(日) | ||||||
| 中京大学体育学部運動生理学研究室 | ||||||
| 著者所属(日) | ||||||
| 中京大学体育学部運動生理学研究室 | ||||||
| 著者所属(英) | ||||||
| en | ||||||
| Laboratory for Exercise Physiology, School of Physical Education, Chukyo University | ||||||
| 著者所属(英) | ||||||
| en | ||||||
| Laboratory for Exercise Physiology, School of Physical Education, Chukyo University | ||||||
| 著者所属(英) | ||||||
| en | ||||||
| Laboratory for Exercise Physiology, School of Physical Education, Chukyo University | ||||||
| 著者所属(英) | ||||||
| en | ||||||
| Laboratory for Exercise Physiology, School of Physical Education, Chukyo University | ||||||
| 抄録(英) | ||||||
| 内容記述タイプ | Other | |||||
| 内容記述 | A portable heart rates (HR) memory system is very convenient for the field study. Such kinds of equipments are now put on the market. They are, however, highly expensive or of capacity of short recording time. Therefore, the authors participated in making a portable and low-priced equipment for recording a day's HR on an experimental basis. This kind of portable equipment has to record HR with a high degree of accuracy however strenuous the exercise may be. The authors forced so hard exercise on the adult male subjects that HR reached to about 200 beats per minute. Then, they led HR from the subject with the above-mentioned equipment and with the polygraph (i.e. direct method) simultaneously. As a result, the discrepancy of HR between two methods was so small as to be negligible for practical use. It has been supposed that this equipment offers an effective means to the field work of health science. | |||||
| 書誌情報 |
中京体育学研究 en : Research journal of physical education, Chukyo University 巻 22, 号 1, p. 15-22, 発行日 1981-11-01 |
|||||
| 表示順 | ||||||
| 内容記述タイプ | Other | |||||
| 内容記述 | 4 | |||||
| アクセション番号 | ||||||
| 内容記述タイプ | Other | |||||
| 内容記述 | KJ00004190148 | |||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 02870088 | |||||